Burner and nozzle specifications
Table 1 Liquid Gas Natural Gas
Burner Diameter Thermal Thermal By-pass Nozzle Flow* Thermal Nozzle Flow*
power power 1/100 1/100 (g/h) power 1/100 (l/h)
kW kW kW
(p.c.s.*) (p.c.s.*) (p.c.s.*)
(mm) Reduced Nominal (mm) (mm) *** ** Nominal (mm)
Supply pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
Reduced Fast (RR)
Semi Fast (S)
Auxiliary (A)
Triple Crown (TC)
Ultrarapid (UR)
Semi-Fishburner (SP)
Double Flame
(DCDR Internal)
Double Flame
(DCDR External)
2 nozzle
100
75
55
130
100
30
130
0.70
0.40
0.40
1.50
0.70
0.70
0.40
1.50
2.60
1.90
1.00
3.30
3.40
1.50
0.90
4.10
39
28
28
61
39
39
28
61
80
70
50
91
91
60
44
70
189
138
73
240
247
109
65
298
186
136
71
236
243
107
64
293
2.60
1.90
1.00
3.60
3.40
1.50
0.90
4.10
110 (Y)
106
79
145 (H1)
123
88
70
114
248
181
95
343
324
143
86
390
* At 15°C and 1013 mbar - dry gas
** Propane P.C.S. = 50.37 MJ/Kg
*** Butane P.C.S. = 49.47 MJ/Kg
Natural P.C.S. = 37.78 MJ/m
3
DC
S
A
SP
DC
TC
S
A
DC
S
A
DC TC
PH 760 RF/HA PH 750 RT GH/HA PH 741 RQO GH/HA PH 720 RT/HA
PH 760 RF GH/HA
PZ 760 RF/HA
DC TC
S
RR
UR
S
S
A
RR
TC
S
S
A
RR
S
A
S
SP
PH 730 RT/HA PH 750/HA PH 750 T/HA PH 760 F/HA
PH 750 T GH/HA PH 760 F GH/HA
! The hob can only be installed above built-in ovens with a cooling ventilation system.