Indesit PKL 642 IX/HA Mode d'emploi Page 15

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 20
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 14
GB
15
Table 1 Liquid Gas Natural Gas
Burner Diameter Thermal Thermal By-pass Nozzle Flow* Thermal Nozzle Flow*
power power 1/100 1/100 (g/h) power 1/100 (l/h)
kW kW kW
(p.c.s.*) (p.c.s.*) (p.c.s.*)
(mm) Reduced Nominal (mm) (mm) *** ** Nominal (mm)
Supply pressures Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
Rapid (R)
Semi Fast (S)
Auxiliary (A)
100
75
55
0.70
0.40
0.40
3.00
1.65
1.00
39
28
28
86
64
50
218
120
73
214
118
71
3.00
1.65
1.00
132(H3)
96(Z)
79(6)
286
157
95
Burner and nozzle specifications (for 65 cm versions only)
* At 15°C and 1013,25 mbar - dry gas
** Propane P. C.S. = 50.37 MJ/Kg
*** Butane P. C.S. = 49.47 MJ/Kg
Natural P. C.S. = 37.78 MJ/m³
R
S
S
A
PKL 642 IX/HA
Vue de la page 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20

Commentaires sur ces manuels