GB
9
Table 1 Liquid gas Natural gas
BURNER
Diameter
(mm)
Thermal Power
kW (p.c.s. *)
By-pass
1/100
(mm)
Nozzle
1/100
Nozzle
1/100
(mm)
Flow *
g/h
Flow *
l/h
(mm)Nomin. Red. G30/31 G20
Fast (Large) (R)
0100 3.00 0.7 40 86 218 116 286
Semi-Fast (Medium) (S)
575 1.65 0.4 30 64 120 96 157
Auxiliary (Small) (A)
55 1.00 0.4 30 50 73 71 95
Triple Crown (TC) 130 3.25 1.3 57 91 236 124 309
Supply pressure
Nominal (mbar)
Minimal (mbar)
Maximised (mbar)
28-30
20
35
20
17
25
* At 15°C and 1013 mbar - dry gas
3
Start-up and use
Using the hob
Lighting the burners
For each BURNER knob there is a complete ring showing
The symbols near the knobs show the position of the
relative burner on the hob.
To light one of the burners on the hob:
2. Press the BURNER knob and turn it in an anticlockwise
.
turning the BURNER knob in an anticlockwise direction.
This may be the minimum setting , the maximum setting
or any position in between the two.
electronic lighting device* (see
and turn it in an anticlockwise
direction, towards the minimum
The burner might be extinguished
when the knob is released. If this
occurs, repeat the process, holding
the knob down for a longer period of time.
!
and wait for at least 1 minute before attempting to relight it.
press and hold the BURNER knob for approximately 2-3
To switch the burner off, turn the knob until it reaches the
stop position .
Practical advice on using the burners
to save on the amount of gas consumed, it is recommended
They should also be suited to the size of the burner.
Burner
Fast (R)
Semi Fast (S)
Auxiliary (A)
Triple Crown (TC)
Ø Cookware Diameter (cm)
24 - 26
16 - 22
10 - 14
24 - 26
reducing pan stands, which should only
be used on auxiliary burner (A).
For the best performance of your burners, keep the following
in mind: All types of pans can be used on the burners. The
important thing is that the bottom should be completely even.
* Only available in certain models.