Indesit GPN 64 CI RFH Mode d'emploi Page 9

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 24
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 8
GB
9
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
Fast (R)
Semi Fast (S)
Auxiliary (A)
100
75
55
0.70
0.40
0.40
3.00
1.65
1.00
39
28
28
86
64
50
218
120
73
214
118
71
3.00
1.65
1.00
132 (H)
96 (Z)
79 (6)
286
157
95
Burner and nozzle specifications
* At 15°C and 1013,25 mbar - dry gas
** Propane P. C.S. = 50.37 MJ/Kg
*** Butane P. C.S. = 49.47 MJ/Kg
Natural P. C.S. = 37.78 MJ/m³
Table 1 Liquid Gas Natural Gas
Supply pressures
Burner
Diameter
(mm)
Thermal
Power
kW (p.c.s.*)
NominalReduced
By-pass
1/100
(mm)
Nozzle
1/100
(mm)
Nozzle
1/100
(mm)
Flow*
g/h
***
**
Flow*
l/h
Thermal
Power
kW (p.c.s.*)
Thermal
Power
kW (p.c.s.*)
Nominal
GPN 64 NCI RFH
R
S
S
A
Vue de la page 8
1 2 3 4 5 6 7 8 9 10 11 12 13 14 ... 23 24

Commentaires sur ces manuels

Pas de commentaire