Indesit PP Q40 TC SF Mode d'emploi Page 20

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 76
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 19
GB
20
Burner and nozzle specifications
Table 1 Liquid gas Natural gas
BURNER
Diameter
(mm)
Thermal power
kW (H.s.*)
By-pass
1/100
(mm)
Injector
1/100
(mm)
Flow *
g/h
Injector
1/100
(mm)
Flow*
l/h
Nomin. Reduc. G30 G31 G20
D.
Triple Ring 130 3.25 1.3 57 91 236 232 124 309
C.
Rapid
100 3.00 0.7 40 86 218 214 116 286
B.
Semi-rapid
75 1.65 0.4 30 64 120 118 96 157
A.
Auxiliary 55 1.00 0.4 30 50 73 71 71 95
I.
Double flame DC DR (internal)
30 0.90 0.4 30 44 65 64 70 86
I.
Double Flame DC DR (external)
130 4.10 1.3 57 70 298 293 110 390
Supply pressure
Nominal
Minimum
Maximum
28-30
20
35
37
25
45
20
17
25
* At 15°C and 1013 mbar - dry gas
** Propane P.C.S. = 50.37 MJ/Kg
*** Butane P.C.S. = 49.47 MJ/Kg
Natural P.C.S. = 37.78 MJ/m3
! The hob can only be installed above built-in ovens with a cooling ventilation system.
BQ 50TC
BQ 40TC
PPF Q40TC BNV
D
C
A
B
B
C
BD
AB
A
I
C
A
B
B
BQ 40DCDR
D
C
A
B
B
C
A
B
B
I
BQ 40TC/CS
PPF Q40TC/CS
PP Q40 TC SF
PP 93 G SF
BQ 40DCDR/CS
PPF Q40DCDR
Vue de la page 19
1 2 ... 15 16 17 18 19 20 21 22 23 24 25 ... 75 76